How we check our own work

Before we test a single patient sample each morning, every analyser runs samples whose answer we already know. The chart is one of them: twenty days of glucose control results, each plotted against the target.

Quality control chart for glucose, twenty days Nineteen results sit within two standard deviations of the target. On day fifteen one result passed two standard deviations, the run was held, the analyser recalibrated and the control repeated before patient results were released. +3 SD +2 SD +1 SD Target -1 SD -2 SD -3 SD Day 15: run held, recalibrated, repeated Day 1 Day 20
Glucose control, Lekki analyser 2. Illustrative data for this demonstration.

From your arm to your report

  1. Collection

    Your identity checked twice, tubes drawn in the order of draw, and labels printed and stuck on in front of you.

  2. Reception

    Every barcode scanned in. Samples checked for clots, too little blood or a broken seal, and logged with a time.

  3. Analysis

    Run only after the morning quality controls pass. If a control fails, nothing is released until the cause is fixed.

  4. Technical review

    A scientist checks each result against the analyser's flags, the sample's history and your previous results.

  5. Clinical review

    A pathologist reviews anything unusual, adds comments and phones urgent results to you or your doctor.

  6. Release

    The signed report goes to your portal and to your doctor at the same moment, with the time it was released.

The quality system behind it

A scientist adding liquid to a row of test tubes
Licensed and registered
Each branch holds the licences required by the national and state health authorities for a medical laboratory and a diagnostic imaging centre, renewed every year and displayed at reception.
Built to the international standard
Our quality manual, document control and audit cycle follow the international standard written for medical laboratories. We describe our system against it openly and are preparing for external assessment.
External quality assessment
Several times a year an independent scheme sends us samples of unknown value. We test them like patient samples and are scored against laboratories worldwide.
Calibration and maintenance
Analysers are calibrated to the maker's schedule and after every major service, with daily, weekly and monthly maintenance logged and checked.
Staff competence
Every scientist and phlebotomist is registered with their professional body, assessed on each method before working alone, and reassessed every year.
Turnaround watched daily
We publish our own turnaround to the team each morning. Any sample close to its promised time is flagged for a supervisor.

The order of draw

Every phlebotomist fills tubes in the same order, so no additive can carry into the next tube. The colours below are the caps you will see.

1 YellowAerobic and anaerobic culture bottles 2 Light blueSodium citrate tube 3 GoldSerum separator tube (SST) 4 GreenLithium heparin tube 5 LavenderEDTA tube 6 GreyFluoride oxalate tube
A white microscope on a dark bench

Have a concern about a result or a visit? Tell us and the laboratory manager will reply within two working days.